Linux Sensors (sysfs)
Plugin: charts.d.plugin Module: sensors
Overview
Use this collector when lm-sensors
doesn't work on your device (e.g. for RPi temperatures).
For all other cases use the Python collector, which supports multiple jobs, is more efficient and performs calculations on top of the kernel provided values."
It will provide charts for all configured system sensors, by reading sensors directly from the kernel. The values graphed are the raw hardware values of the sensors.
This collector is only supported on the following platforms:
- Linux
This collector supports collecting metrics from multiple instances of this integration, including remote instances.
Default Behavior
Auto-Detection
By default, the collector will try to read entries under /sys/devices
Limits
The default configuration for this integration does not impose any limits on data collection.
Performance Impact
The default configuration for this integration is not expected to impose a significant performance impact on the system.
Metrics
Metrics grouped by scope.
The scope defines the instance that the metric belongs to. An instance is uniquely identified by a set of labels.
Per sensor chip
Metrics related to sensor chips. Each chip provides its own set of the following metrics.
This scope has no labels.
Metrics:
Metric | Dimensions | Unit |
---|---|---|
sensors.temp | {filename} | Celsius |
sensors.volt | {filename} | Volts |
sensors.curr | {filename} | Ampere |
sensors.power | {filename} | Watt |
sensors.fans | {filename} | Rotations / Minute |
sensors.energy | {filename} | Joule |
sensors.humidity | {filename} | Percent |
Alerts
There are no alerts configured by default for this integration.
Setup
Prerequisites
Install charts.d plugin
If using our official native DEB/RPM packages, make sure netdata-plugin-chartsd
is installed.
Enable the sensors collector
The sensors
collector is disabled by default. To enable it, use edit-config
from the Netdata config directory, which is typically at /etc/netdata
, to edit the charts.d.conf
file.
cd /etc/netdata # Replace this path with your Netdata config directory, if different
sudo ./edit-config charts.d.conf
Change the value of the sensors
setting to force
and uncomment the line. Save the file and restart the Netdata Agent with sudo systemctl restart netdata
, or the appropriate method for your system.
Configuration
File
The configuration file name for this integration is charts.d/sensors.conf
.
You can edit the configuration file using the edit-config
script from the
Netdata config directory.
cd /etc/netdata 2>/dev/null || cd /opt/netdata/etc/netdata
sudo ./edit-config charts.d/sensors.conf
Options
The config file is sourced by the charts.d plugin. It's a standard bash file.
The following collapsed table contains all the options that can be configured for the sensors collector.
Config options
Name | Description | Default | Required |
---|---|---|---|
sensors_sys_dir | The directory the kernel exposes sensor data. | /sys/devices | no |
sensors_sys_depth | How deep in the tree to check for sensor data. | 10 | no |
sensors_source_update | If set to 1, the script will overwrite internal script functions with code generated ones. | 1 | no |
sensors_update_every | The data collection frequency. If unset, will inherit the netdata update frequency. | 1 | no |
sensors_priority | The charts priority on the dashboard. | 90000 | no |
sensors_retries | The number of retries to do in case of failure before disabling the collector. | 10 | no |
Examples
Set sensors path depth
Set a different sensors path depth
# the directory the kernel keeps sensor data
#sensors_sys_dir="/sys/devices"
# how deep in the tree to check for sensor data
sensors_sys_depth=5
# if set to 1, the script will overwrite internal
# script functions with code generated ones
# leave to 1, is faster
#sensors_source_update=1
# the data collection frequency
# if unset, will inherit the netdata update frequency
#sensors_update_every=
# the charts priority on the dashboard
#sensors_priority=90000
# the number of retries to do in case of failure
# before disabling the module
#sensors_retries=10
Troubleshooting
Debug Mode
To troubleshoot issues with the sensors
collector, run the charts.d.plugin
with the debug option enabled. The output
should give you clues as to why the collector isn't working.
Navigate to the
plugins.d
directory, usually at/usr/libexec/netdata/plugins.d/
. If that's not the case on your system, opennetdata.conf
and look for theplugins
setting under[directories]
.cd /usr/libexec/netdata/plugins.d/
Switch to the
netdata
user.sudo -u netdata -s
Run the
charts.d.plugin
to debug the collector:./charts.d.plugin debug 1 sensors